LUDZERN CORIOLIS MASS FLOW METER ALAT UKUR MASA
The LZN6000 Series uses the Coriolis effect as a technique for liquid mass flow measurement.
The LZN6000 can measure most of the liquids; the infrared light sensor makes it easy for you to set parameters & change the display data. The Double-C tube & Double-D Tube make it possible for the meter to be used in most liquid applications.
Description
Can be programmed by infrared light sensor without opening cover
High turndown ratio of flow rate
It comes any flanges such as ANSI, DIN, JIS etc.
Excellent for high pressure application
Simple for installation, commission and maintenance
Self-diagnostic capabilities, cable faults, pipe vibration
High accuracy of +/-0.2% of reading (or +/-0.1% of reading)
With forward / reverse flow rate measurement function
Sensor Type : C tube (5-40 mm) / U tube (50-250 mm)
Size : 15-250 mm (1/2″-10″)
Flow Range : 0-240 kg/hr~0-2200 t/hr
Accuracy : +/-0.2% +/-ZS of reading (Standard)
: +/-0.1% +/-ZS of reading (Optional)
Repeatability : +/-0.03% +/-ZS of reading
Density Range : 200-2300 kgf/m3 (0.2-2.3 g/cm3)
Accuracy : +/-0.002 g/cm3
Temperature Range: -40~125 °C (Standard)
: -40~250 °C (Optional, Remote Only)
Material
Wetted Parts : Stainless Steel 316L
Flange : Stainless Steel 316L
Sensor Housing : Stainless Steel 304
Junction Box : Aluminum Alloy (Epoxy Paint)
Process Connection : Flange
Flange Type : JIS 10K / JIS 20K / JIS 40K
: ANSI 150# / ANSI 300# / ANSI 600#
: DIN PN10 / PN16 / PN25 / PN40
Protection Class : IP67
: Explosion Proof, Ex d e [ib] IIC T6 (Optional)
Installation : Compact or Remote
Signal Cable Length : 10-100 m
Display : 2 lines LCD with illumination
Flow Rate Unit : g/s, kg/m, kg/hr, t/hr, lb/m, USgal/m (6 Digit)
Density Unit : kg/m3, g/cm3 (6 Digit)
Totalizer Unit : g, kg, Ton, L, m3, Nm3, lb, USgal (7 Digit)
Temperature : °C, °F (4 Digit)
Keypad : Infrared light Sensor, can be programmed
without opening the cover
Turndown Ratio : 20:1
Damping : 0.01-1.0 Seconds
Low Flow Cutoff : 0.0-9.0%
Communication : RS485 (Modbus Protocol) (Standard)
: HART Signal (Optional)
Current Output : 4-20 mA (Isolated)
Load : Max. 750 Ω
Output Unit : Mass / Volume / Density / Temperature
Pulse (Alarm) Output : Open Collector
Rating : 3-30 VDC, 50 mA Max.
Power Supply : 90-260 VAC, 50/60 Hz or 24 VDC +/-10%
Power Consumption : 30-40 W (Depend on sensor size)
Cable Entry : Sensor to Converter-3/4″ G
: Signal output / Power supply-M20
Ambient Temperature : -40~60 °C
Max. Pressure : 63 kgf/cm2